Jump to the main text

Thermal and Hydro Power Systems

Hitachi

Hitachi can supply many different types of steam turbines from small to large capacity for various steam conditions.

Supply Experience

table : Supply Experience
Unit Rating Number of Units
up to 99 MW 1065
100 to 199 MW 72
200 to 299 MW 51
300 to 499 MW 57
500 to 999 MW 36
1000 MW & Over 19
Total 1300

image

  • Rated Output : 700 MW
  • Turbine Type : Tandem-compound Four Flow Exhaust Reheat Czzondensing with 40" LSB
  • Revolution : 3,600 rpm
  • Main Steam Press. : 24.1 Mpa
  • Main & Reheat Steam Temp. : 538 / 566degrees celsius
  • Condenser Vacuum : -96.26 kPa
  • Initial Operation : 1992

image

  • Rated Output : 1,000 MW
  • Turbine Type : Cross-compound Four Flow Exhaust Reheat Condensing with 41" LSB CC4F-41
  • Revolution : 3,000 / 1,500 rpm
  • Main Steam Press. : 24.5 Mpa
  • Main & Reheat Steam Temp. : 600 / 600degrees celsius
  • Condenser Vacuum : -97.06 kPa
  • Initial Operation : 1998 / 7

image

  • Rated Output : 700 MW
  • Turbine Type : Tandem-compound Four Flow Exhaust Reheat Condensing with 43" LSB 3casings (HIP, 2LP) TC4F-43 (12Cr Steel)
  • Revolution : 3,000 rpm
  • Main Steam Press. : 25.0 Mpa
  • Main & Reheat Steam Temp. : 600 / 600degrees celsius
  • Condenser Vacuum : -98.0 kPa
  • Initial Operation : 2002 / 6